Ethernet slip rings
MOFLON ME Series Ethernet slip rings
Slip rings carrying one or two 10/100/1000 Mbit/s Ethernet channels alongside 5 A and 10 A power and signal circuits, in capsule (22 mm) and through-bore versions up to 50 mm bore and 119 mm diameter, with RJ45 or M12 connectors.
Need this part, a replacement or a complete package? Our experienced UK engineering team helps you select, source and obtain the right products, with pricing, delivery coordination and after-sales support.
Pricing and availability
Get pricing, sourcing and replacement support
Need MOFLON parts, a replacement or a suitable alternative? Send us a part number, or tell us what the machine needs to do. Our UK engineers will come back with the right product, pricing, lead time and delivery, whether that is the original part, a checked alternative or a complete axis.
- Original parts or a checked alternative
- Pricing, lead time and delivery in one reply
- Components, complete axes and ongoing support
No obligation. Add what you know and an engineer will help with the rest. Prefer to configure it? Build a specification.
Spec builder
Specify what you need instead of ME Series Ethernet slip rings
Select every part you need and answer the questions an applications engineer would ask. Our engineers use your specification to come back with the right products, pricing and lead times. You see your summary before we ask for any details.
Already know the part number? Send it to us directly.
- 1Products
- 2Performance
- 3Environment
- 4Volumes
- 5Your spec
What are you specifying?
Select everything you need. A motor, drive and gearbox can be specified together as one axis.
Key specifications
| Circuits (max) | 46 |
|---|---|
| Current per circuit (max) | 10 A |
| Bore (max) | 50 mm |
| Outer diameter | 22–119 mm |
| Data / bus | Ethernet 10/100/1000 Mbit/s |
| Ethernet channels max | 2 |
| Connectors | RJ45 or M12 |
| Circuits note | model table up to 46 mixed circuits; page says standard models 6 to 108 circuits |
Summarised in our own words from MOFLON Technology (legal entity name not stated on its website)'s published data; series maxima, individual models vary. Last checked 2026-10-30. Source 1 · Source 2
Notes on this data
Voltage, speed, IP and temperature not published on the series page.
Specify Motion is not affiliated with MOFLON Technology (legal entity name not stated on its website). MOFLON and ME Series Ethernet slip rings are used only to identify the product. Comparisons use published figures; always confirm against the current datasheet.
MOFLON ME Series Ethernet slip rings replacement and alternative options
Use these supply-network options as a starting point for an engineering check. We can also help source the original MOFLON part. Published series figures do not establish an exact-model or drop-in replacement: confirm ratings, fit, interfaces and approvals for your application.
Slip rings with dedicated 100M or Gigabit Ethernet channels alongside power and signal circuits, offered in solid-shaft and through-bore forms.
| Published maximum | ME Series Ethernet slip rings | Ethernet Slip Ring |
|---|---|---|
| Circuits | 46 | 100 meets or exceeds |
| Current per circuit | 10 A | 30 A meets or exceeds |
| Speed | — | 300 rpm |
| Voltage | — | 240 V |
| Bore | 50 mm | 100 mm meets or exceeds |
Figures are the highest published for each series and are not always measured the same way. A higher figure is not automatically a better choice: mounting, duty cycle, feedback, connectors and approvals matter too. An engineer will check the fit against your application before recommending anything.
Typical applications
What an ethernet slip ring is
An Ethernet slip ring is a rotary joint designed to pass industrial Ethernet, such as 100 Mbit/s or gigabit links, through continuous rotation without unacceptable packet loss. The data rings are laid out as matched pairs with controlled impedance, short stubs and screening from power rings, and the brushes are chosen for low, stable contact resistance. Some units use contactless capacitive, inductive or optical channels for the highest rates. Most combine the Ethernet channels with power and discrete signal rings in one housing.
When engineers choose an ethernet slip ring
Choose an Ethernet slip ring when the rotating part carries cameras, drives, remote I/O or sensors on a network, which cuts the ring count compared with hard-wiring every signal. It suits indexing machines, packaging turrets and gimbals running EtherCAT, PROFINET or EtherNet/IP. The trade-offs are cost and validation: contact rings add small resistance changes, and gigabit links are more sensitive than 100 Mbit/s. For very high data rates, long life or high speed, a fibre optic or contactless channel may be better.
How to specify the MOFLON ME Series Ethernet slip rings
Send these with your enquiry and an engineer can confirm the right ME Series Ethernet slip rings variant or an equivalent:
- Protocol and data rate, such as EtherCAT, PROFINET or gigabit Ethernet
- Number of Ethernet channels and pairs per channel
- Required test standard or bit error rate target
- Power circuits and current per circuit (A)
- Speed (rpm) and expected life (revolutions)
- Cable type and connectors on each side, such as RJ45 or M12
- Cable lengths to the nearest switch or node (m)
Common mistakes to avoid
- Specifying gigabit when the network only needs 100 Mbit/s, which adds cost and complexity
- Ignoring the cable runs on each side, which count towards the total channel length and loss
- Routing motor power next to data rings without screening or separation
- Not testing the full link with the real protocol under rotation before production
MOFLON ME Series Ethernet slip rings: frequently asked questions
Can you help replace MOFLON ME Series Ethernet slip rings or source the original?
Send the full model code, quantity and required date. Our engineers can check original-part availability and assess suitable alternatives, including supply-network options where appropriate. We confirm compatibility and any changes needed before recommending a replacement.
What is the MOFLON ME Series Ethernet slip rings?
Slip rings carrying one or two 10/100/1000 Mbit/s Ethernet channels alongside 5 A and 10 A power and signal circuits, in capsule (22 mm) and through-bore versions up to 50 mm bore and 119 mm diameter, with RJ45 or M12 connectors. Published series figures include circuits 46, current per circuit 10 A, bore 50 mm, outer diameter 22 mm. It is made by MOFLON Technology (legal entity name not stated on its website); Specify Motion can help source it or propose an equivalent.
Who makes the MOFLON ME Series Ethernet slip rings?
The MOFLON ME Series Ethernet slip rings is made by MOFLON (MOFLON Technology (legal entity name not stated on its website)) and is listed here for engineers comparing options. Specify Motion is not affiliated with MOFLON Technology (legal entity name not stated on its website); brand names are used only to identify the product.
What is the circuits of the MOFLON ME Series Ethernet slip rings?
The published series maximum circuits is 46. Individual models and sizes in the ME Series Ethernet slip rings range vary, so check the exact variant against your duty cycle, mounting and environment, or ask our engineers to confirm the right size for you.
Is there an alternative to the MOFLON ME Series Ethernet slip rings?
We can assess suitable replacement options. On published figures, Motion Control Products Ethernet Slip Ring is options to assess from our supply network. An engineer confirms the fit against your application before recommending anything.
Can EtherCAT and PROFINET run through a slip ring?
Yes, when the slip ring is designed for it. Real-time protocols are sensitive to link drops, so the data rings need controlled impedance, good screening and stable contact resistance. Tell the supplier the protocol, cycle time and number of nodes on the rotating side, and test the full network under rotation. Many suppliers validate their Ethernet rings against standard cabling test methods.
What is the difference between a contact and a contactless Ethernet slip ring?
A contact slip ring passes the signal through brushes on rings, which is economical and handles 100 Mbit/s and often gigabit links well. A contactless channel uses capacitive, inductive or optical coupling, so there is no wear on the data path and very high rates or speeds are possible. Contactless channels cost more and usually still need contact rings for power.
Further reading: Ethernet through slip rings · How to select a slip ring · Slip rings
Other ethernet slip rings series
Engineer support
Let our experienced engineers do the hard work for you
Tell us how you use the MOFLON ME Series Ethernet slip rings: the load, speed, duty and environment. Our engineers will confirm whether it is still the right part, find it for you, or propose an alternative that fits better.
- Reviewed by an engineer, not an autoresponder
- Like-for-like and better-fit alternatives
- Standard, modified and custom options
Prefer to configure it? Use the spec builder.
How it works
From enquiry to delivery
Send a part number or describe the application. Our engineers take it from there: the right product, a clear quotation, and delivery and support arranged.
- 01Tell us what you needSend a part number, or configure the application, quantities and timing.
- 02An engineer reviews itWe check the specification and find the original part, a checked equivalent or a complete axis.
- 03Receive your quotationProducts, pricing, lead time and compatibility notes in one reply.
- 04Order and deliveryWhen you are happy, the order is placed and delivery and after-sales support are arranged.
