Skip to content

Iron-core linear motor

Tecnotion TB iron core linear motors

Heavy-duty iron-core linear motors (TB12 to TB30) for high loads and long duty cycles with 760 to 1,900 N continuous, 4,000 N peak and 4,500 N ultimate force.

Key specifications

Peak force (max)4,000 N
Continuous force (max)1,900 N
Force ultimate4,500

Summarised in our own words from Tecnotion B.V.'s published data; series maxima, individual models vary. Last checked 2026-10-30. Source 1

Specify Motion is not affiliated with Tecnotion B.V.. Tecnotion and TB iron core linear motors are used only to identify the product. Comparisons use published figures; always confirm against the current datasheet.

Typical applications

Machine toolingWoodworkingHeavy gantries

Alternatives that meet or exceed these figures

Engineers often come to us with a Tecnotion part number and leave with an alternative that is easier to source, quicker to deliver or a better fit for the machine. These 3 series from our supply network are the closest match on published figures.

Iron-core linear motor

Akribis Systems AKM

Meets or exceeds on both published figures compared

High-force iron-core linear motors in five widths with optional water cooling, reaching several kN continuous.

Published maximumTB iron core linear motorsAKM
Peak force4,000 N12,884.3 N meets or exceeds
Continuous force1,900 N6,190.1 N meets or exceeds
Speed—5 m/s
View AKM →
Ironless linear motor

Akribis Systems AUM

Meets or exceeds on both published figures compared

U-channel ironless linear motors with zero cogging, six sizes from 3 N to nearly 2 kN continuous, for fast settling precision stages.

Published maximumTB iron core linear motorsAUM
Peak force4,000 N16,200 N meets or exceeds
Continuous force1,900 N1,980 N meets or exceeds
Speed—5 m/s
View AUM →
Meets or exceeds on 1 of 2 figures

High-force cylindrical voice coils from 14 to 250 mm, reaching over 1 kN continuous for heavy short-stroke force control.

Published maximumTB iron core linear motorsAVM High-Force (AVM-HF)
Peak force4,000 N4,715.2 N meets or exceeds
Continuous force1,900 N1,111.4 N
Stroke—35 mm
View AVM High-Force (AVM-HF) →

Figures are the highest published for each series and are not always measured the same way. A higher figure is not automatically a better choice: mounting, duty cycle, feedback, connectors and approvals matter too. An engineer will check the fit against your application before recommending anything.

What an iron-core linear motor is

An iron-core linear motor is a direct-drive linear motor whose coils are wound on a laminated iron core in the moving forcer, running over a flat track of permanent magnets. Current in the coils interacts with the magnet field to produce thrust directly, with no screw, belt or gearbox. The iron core concentrates the magnetic flux, so force density is high and heat can be conducted away through the core. Position feedback comes from a linear encoder.

When engineers choose an iron-core linear motor

Choose an iron-core linear motor for high continuous force, high acceleration and long strokes, such as machine tools, gantries and heavy automation. Direct drive removes backlash and wear in the transmission. The trade-offs are cogging, which causes small force ripple, and a strong attraction force between forcer and magnet track, often many times the rated thrust, which must be carried by the guides. For very smooth, low-ripple motion with light loads, an ironless motor may suit better.

How to specify the Tecnotion TB iron core linear motors

Send these with your enquiry and an engineer can confirm the right TB iron core linear motors variant or an equivalent:

  • Peak and continuous force (N)
  • Stroke and speed (mm, m/s)
  • Moving mass and acceleration (kg, m/s²)
  • Attraction force and guide load capacity (N)
  • Cooling: natural, forced air or water
  • Bus voltage and drive current (V, A)
  • Linear encoder type and resolution

Common mistakes to avoid

  • Sizing guides without including the magnetic attraction force
  • Ignoring cogging in smooth-scan or low-speed applications
  • Leaving out heat dissipation into the machine structure
  • Allowing ferrous debris to collect on the open magnet track

Tecnotion TB iron core linear motors: frequently asked questions

What is the Tecnotion TB iron core linear motors?

Heavy-duty iron-core linear motors (TB12 to TB30) for high loads and long duty cycles with 760 to 1,900 N continuous, 4,000 N peak and 4,500 N ultimate force. Published series figures include peak force 4,000 N, continuous force 1,900 N. It is made by Tecnotion B.V.; Specify Motion can help source it or propose an equivalent.

Who makes the Tecnotion TB iron core linear motors?

The Tecnotion TB iron core linear motors is made by Tecnotion (Tecnotion B.V.) and is listed here for engineers comparing options. Specify Motion is not affiliated with Tecnotion B.V.; brand names are used only to identify the product.

What is the peak force of the Tecnotion TB iron core linear motors?

The published series maximum peak force is 4,000 N. Individual models and sizes in the TB iron core linear motors range vary, so check the exact variant against your duty cycle, mounting and environment, or ask our engineers to confirm the right size for you.

Is there an alternative to the Tecnotion TB iron core linear motors?

Yes. On published figures, Akribis Systems AKM and Akribis Systems AUM are the closest match from our supply network. An engineer confirms the fit against your application before recommending anything.

What is the difference between iron-core and ironless linear motors?

Iron-core motors wind coils on an iron core, giving higher force and better heat removal, but with cogging and a strong magnetic attraction to the track. Ironless motors have coils without iron running between two rows of magnets, so there is no cogging or attraction, giving very smooth motion with lower force and less heat capacity.

Why does an iron-core linear motor need strong guides?

The iron core is strongly attracted to the magnet track, typically with a force several times the rated thrust. That load acts on the guide bearings all the time, even at rest. Guides must be sized for payload, process forces and this attraction, or bearing life will be much shorter than expected.

Further reading: How to select a linear motor · Linear actuators

Other iron-core linear motor series

Spec builder

Specify what you need instead of TB iron core linear motors

Select every part you need, answer the questions an applications engineer would ask, and see your summary before we ask for any details.

  1. 1Products
  2. 2Performance
  3. 3Environment
  4. 4Volumes
  5. 5Your spec
Step 1 of 5

Engineer support

Let our experienced engineers do the hard work for you

Tell us how you use the Tecnotion TB iron core linear motors: the load, speed, duty and environment. Our engineers will confirm whether it is still the right part, find it for you, or propose an alternative that fits better.

  • Reviewed by an engineer, not an autoresponder
  • Like-for-like and better-fit alternatives
  • Standard, modified and custom options

Prefer to configure it? Use the spec builder.

We use your details to answer this enquiry and share them with the specialist engineering and supply partner best placed to fulfil it. See our privacy notice.