LinMot's largest 48 mm P01 tubular motor, giving over 1 kN peak on a 48/72 VDC supply. Stainless-steel versions are available for hygienic and wash-down use.

Key specifications

Ingress protectionIP65
Peak force (max)1,020 N
Continuous force (max)408 N
Stroke (max)1,840 mm
Linear speed (max)4.1 m/s

Summarised in our own words from NTI AG's published data; series maxima, individual models vary. Last checked 2026-10-29. Source 1 · Source 2 · Source 3 · Source 4 · Source 5

Notes on this data

1020 N peak (at 72 VDC, P01-48x360F-HP) and 408 N sustained (P01-48 HP) are from linmot.com. The x360F-HP datasheet gives 374 N continuous with fan cooling. Stroke sources disagree: linmot.com lists 1710 mm, the P01-48x240F datasheet 1830 mm, and the P01-48x150G-HP datasheet 1840 mm extended stroke (the value used). The 4.1 m/s speed is for P01-48x150G-HP at 72 VDC. IP65 is the standard motor rating; SSC stainless stators are listed as IP69K.

Specify Motion is not affiliated with NTI AG. LinMot and P01-48 (incl. P01-48 HP) are used only to identify the product. Comparisons use published figures; always confirm against the current datasheet.

Typical applications

Heavy pick-and-placeForming and pressingFood and pharma (stainless versions)Packaging

Alternatives that meet or exceed these figures

Engineers often come to us with a LinMot part number and leave with an alternative that is easier to source, quicker to deliver or a better fit for the machine. These 3 series from our supply network are the closest match on published figures.

Iron-core linear motor

Akribis Systems AQM

Meets or exceeds on all 4 published figures compared

Narrow, cost-effective iron-core linear motors with low cogging for long-stroke, space-constrained axes.

Published maximumP01-48 (incl. P01-48 HP)AQM
Peak force1,020 N1,243 N meets or exceeds
Continuous force408 N506 N meets or exceeds
Speed4.1 m/s5 m/s meets or exceeds
Stroke1,840 mm100,000 mm meets or exceeds
View AQM →
Ironless linear motor

Akribis Systems AUM

Meets or exceeds on all 3 published figures compared

U-channel ironless linear motors with zero cogging, six sizes from 3 N to nearly 2 kN continuous, for fast settling precision stages.

Published maximumP01-48 (incl. P01-48 HP)AUM
Peak force1,020 N16,200 N meets or exceeds
Continuous force408 N1,980 N meets or exceeds
Speed4.1 m/s5 m/s meets or exceeds
Stroke1,840 mm—
View AUM →
Ironless linear motor

Akribis Systems AWM

Meets or exceeds on all 3 published figures compared

Vacuum-compatible ironless linear motors with high motor constant and zero cogging, six sizes.

Published maximumP01-48 (incl. P01-48 HP)AWM
Peak force1,020 N3,845.3 N meets or exceeds
Continuous force408 N769.1 N meets or exceeds
Speed4.1 m/s5 m/s meets or exceeds
Stroke1,840 mm—
View AWM →

Figures are the highest published for each series and are not always measured the same way. A higher figure is not automatically a better choice: mounting, duty cycle, feedback, connectors and approvals matter too. An engineer will check the fit against your application before recommending anything.

Other tubular linear motor series

Spec builder

Specify what you need instead of P01-48 (incl. P01-48 HP)

Select every part you need, answer the questions an applications engineer would ask, and see your summary before we ask for any details.

  1. 1Products
  2. 2Performance
  3. 3Environment
  4. 4Volumes
  5. 5Your spec
Step 1 of 5

Engineer support

Let our experienced engineers do the hard work for you

Tell us how you use the LinMot P01-48 (incl. P01-48 HP): the load, speed, duty and environment. Our engineers will confirm whether it is still the right part, find it for you, or propose an alternative that fits better.

  • Reviewed by an engineer, not an autoresponder
  • Like-for-like and better-fit alternatives
  • Standard, modified and custom options

Prefer to configure it? Use the spec builder.

We use your details to answer this enquiry and share them with the specialist engineering and supply partner best placed to fulfil it. See our privacy notice.

Ask an engineer